SKU: N/A

EUROMAP 73 for injection molding machine

1.00 kr

Clear
,

Product information

Protection class
IP65
In-/Outputs
14
Harting contact
16B

Description

Advantages

  • Plug & Play: Safety Simplifier units with matching safety door protection for each door and with prepared EPlan macros, makes planning and design easier
  • Flexible safety concept without safety controller in the control cabinet, which must be wired and planned
  • Easily expandable for up to 15 doors
  • In retrofit systems, modern door switches with RFID can replace existing doors with 3 safety switches
  • Easy maintenance and commissioning with the free software Simplifier Manager

EUROMAP 73 requires three safety switches per safety door. A plausibility check during opening and closing of the door is used to check for manipulation of the safety functions. Only one safety door with three safety switches can be connected to a EUROMAP 73 interface.

If further accesses to a plant are required, additional EUROMAP 73 interfaces are needed from the manufacturer of the plant, or a safety controller is installed in a control cabinet. If a safety controller is used, the safety function of several doors is connected to the injection molding system with a contact extension in the control cabinet (3 NO contacts and 3 NC contacts).

Read more

Advantages

  • Plug & Play: Safety Simplifier units with matching safety door protection for each door and with prepared EPlan macros, makes planning and design easier
  • Flexible safety concept without safety controller in the control cabinet, which must be wired and planned
  • Easily expandable for up to 15 doors
  • In retrofit systems, modern door switches with RFID can replace existing doors with 3 safety switches
  • Easy maintenance and commissioning with the free software Simplifier Manager

EUROMAP 73 requires three safety switches per safety door. A plausibility check during opening and closing of the door is used to check for manipulation of the safety functions. Only one safety door with three safety switches can be connected to a EUROMAP 73 interface.

If further accesses to a plant are required, additional EUROMAP 73 interfaces are needed from the manufacturer of the plant, or a safety controller is installed in a control cabinet. If a safety controller is used, the safety function of several doors is connected to the injection molding system with a contact extension in the control cabinet (3 NO contacts and 3 NC contacts).

With Safety Simplifier

A Safety Simplifier on an injection molding machine with integrated EUROMAP 73 interface is a simple and flexible solution. Up to 15 external doors and operational units can be wirelessly connected and integrated with the injection molding machine. This means no additional control cabinet and no additional safety controller in the control cabinet and significantly less wiring effort.

Existing doors with 3 safety switches or doors with state-of-the-art, highly coded RFID actuators can be individually networked with a Safety Simplifier with EUROMAP 73 interface.

The Safety Simplifier is not only the ideal solution for large plants, but is often the most economical solution from the very first door, since a separate evaluation in the control cabinet is not necessary. Safety functions, material transport, rear step protection by means of safety laser scanners, safety light curtains, safety mats or pre-reset buttons can be easily integrated.

The Safety Simplifier helps to bring older systems up to the latest safety standards and considerably simplifies the integration.

Documents

Technical Data

General data
Article number
SP-X-89-100-27
Functional type
Safety- PLC with safe wireless interface, internal antenna, Euromap 73 connection
- Position 1
Q1A0 - Connection bottom left with cover
- Position 2
Q2Z0 - Connection top left Euromap with Harting connector 1m cable
- Position 3
Q3A0 - connection bottom right with cover
- Position 4
Q4A0 - Connection top right with cover
Safety data
CPU
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel input
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2-channel input
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel OSSD output
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel OSSD Output
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel relais output
- EN ISO 13849-1: 2008
Category 4
- EN 62061 SIL CIL
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
Environmental conditions
Max. storage temperature
-20 °C ... +65 °C
Max. operating temperature
-20 °C ... +65 °C
Electrical data
Technical data wireless safety
- max. amount of safe wireless channels
16
Channels
- Channel 1
2405 MHz
- Channel 2
2410 MHz
- Channel 3
2415 MHz
- Channel 4
2420 MHz
- Channel 5
2425 MHz
- Channel 6
2430 MHz
- Channel 7
2435 MHz
- Channel 8
2440 MHz
- Channel 9
2445 MHz
- Channel 10
2450 MHz
- Channel 11
2455 MHz
- Channel 12
2460 MHz
- Channel 13
2465 MHz
- Channel 14
2470 MHz
- Channel 15
2475 MHz
- Channel 16
2480 MHz
- amount of clamps
32
Supply voltage
10 - 30 V
Current consumption
110 mA with LED display
Conductor cross section
- single wire
0,08 … 0,5 mm²
- fine wire
0,08 … 0,5 mm²
- fine wired (wire sleeve without plastic collar)
0,25 mm²
Configurable In-/ Outputs
14 semiconductor In-/ Outputs with help of software configurable
Amount of safe inputs
max. 14
Amount of safe semi-conductors OSSD outputs m
max. 14
Amount of semi-conductors auxilliary outputs
max. 14
Amount of semi-conductors clock outputs
max. 8
Input current
HIGH 2,4 mA ... 3,8 mA LOW -2,5 mA ... 2,1 mA
Output type
PNP- Semiconductor
Output voltage
Operating Voltage UB -0,5 V
Seperate output current
max. 600 mA (bei UB 24 V)
Total output current
max. 2 A (bei UB 24 V)
General data
Memory card
Installation of a memory card MEM SP-N-88-001-93 possible
Programming connection
Installation of a memory card MEM SP-N-88-001-93 possible
Programming connection
Micro USB Wireless-Interface
- fine wired (wire sleeve with plastic collar)
0,08 … 0,5 mm²
Input voltage
HIGH 75% from UB (adjustable by software) LOW 25% from UB (adjustable by software)
Technical data inputs
Technical data safe OSSD outputs, auxilliary and test pulse outputs
Short-circuit proof
Yes
Mechanical data
Installation opening of buttons
22,5 mm
Type of housing
H00
Dimensions
Height
44 mm
Length
253 mm
Width
42 mm

Recommended