SKU: N/A

EUROMAP 78 for injection molding machine

1.00 kr

Clear
,

Product information

Protection class
IP65
In-/Outputs
14
Harting contact
10B

Description

Advantages

  • Safety outputs pin a7 and b7 are only switched on after confirmation of the safety switches
  • Connection of up to 15 doors to one EUROMAP interface
  • Wireless communication for fast, wiring-reduced commissioning
  • No need to use additional safety controllers
  • Emergency stop functions can switch off further peripheral systems via the wireless interface
  • Unproblematic plant expansion using additional safety doors is possible in a short period of time

The EUROMAP 78 defines the connection between an injection molding machine and an external safety device. It requires a two-channel safe signal (OSSD) according to the specified performance level, which can be provided by a safety switch and/or a safety controller.

The safety signals at pins a7 and b7 of the EUROMAP 78 may only switch on when the safety device is closed, locked and confirmed.

Only one safety switch/emergency stop button can be connected directly to a EUROMAP 78 interface at a time. If more safety doors are required, an additional interface must be requested from the manufacturer of the injection molding machine or an additional safety controller in an external control cabinet takes over the connection of several safety doors to one EUROMAP 78 interface.

Read more

Advantages

  • Safety outputs pin a7 and b7 are only switched on after confirmation of the safety switches
  • Connection of up to 15 doors to one EUROMAP interface
  • Wireless communication for fast, wiring-reduced commissioning
  • No need to use additional safety controllers
  • Emergency stop functions can switch off further peripheral systems via the wireless interface
  • Unproblematic plant expansion using additional safety doors is possible in a short period of time

The EUROMAP 78 defines the connection between an injection molding machine and an external safety device. It requires a two-channel safe signal (OSSD) according to the specified performance level, which can be provided by a safety switch and/or a safety controller.

The safety signals at pins a7 and b7 of the EUROMAP 78 may only switch on when the safety device is closed, locked and confirmed.

Only one safety switch/emergency stop button can be connected directly to a EUROMAP 78 interface at a time. If more safety doors are required, an additional interface must be requested from the manufacturer of the injection molding machine or an additional safety controller in an external control cabinet takes over the connection of several safety doors to one EUROMAP 78 interface.

With Safety Simplifier

Safety switches, process locks or RFID sensors can be easily connected to a Safety Simplifier via an M12 plug. This is mounted directly on the safety gate.

Thanks to secure wireless or CAN communication, up to 15 safety gates can be connected to one EUROMAP 78 interface with the Safety Simplifier. The EUROMAP Safety Simplifier is connected directly to the injection molding machine via a fixed cable with Harting plug.

Safety functions such as emergency stop, door request or reset are implemented directly in the Safety Simplifier and can be configured in the Simplifier Manager software without any programming knowledge. Thanks to ready-to-use functional modules and prescribed programs, the programming of the safety controller is quick and easy.

The safe OSSD outputs are only enabled after all doors have been closed, held shut and acknowledged.

Documents

Technical Data

General data
Article number
SP-X-89-100-31
Functional type
Safety- PLC with safe wireless interface, internal antenna, Euromap 78 connection
- Position 1
Q1A0 - Connection bottom left with cover
- Position 2
Q2A1 - Connection top left Harting 10B - Euromap 78
- Position 3
Q3A0 - connection bottom right with cover
- Position 4
Q4A0 - Connection top right with cover
Safety data
CPU
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel input
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2-channel input
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel OSSD output
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel OSSD Output
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel relais output
- EN ISO 13849-1: 2008
Category 4
- EN 62061 SIL CIL
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
Environmental conditions
Max. storage temperature
-20 °C ... +65 °C
Max. operating temperature
-20 °C ... +65 °C
Electrical data
Technical data wireless safety
- max. amount of safe wireless channels
16
Channels
- Channel 1
2405 MHz
- Channel 2
2410 MHz
- Channel 3
2415 MHz
- Channel 4
2420 MHz
- Channel 5
2425 MHz
- Channel 6
2430 MHz
- Channel 7
2435 MHz
- Channel 8
2440 MHz
- Channel 9
2445 MHz
- Channel 10
2450 MHz
- Channel 11
2455 MHz
- Channel 12
2460 MHz
- Channel 13
2465 MHz
- Channel 14
2470 MHz
- Channel 15
2475 MHz
- Channel 16
2480 MHz
- amount of clamps
32
Supply voltage
10 - 30 V
Current consumption
110 mA with LED display
Conductor cross section
- single wire
0,08 … 0,5 mm²
- fine wire
0,08 … 0,5 mm²
- fine wired (wire sleeve without plastic collar)
0,25 mm²
Configurable In-/ Outputs
14 semiconductor In-/ Outputs with help of software configurable
Amount of safe inputs
max. 14
Amount of safe semi-conductors OSSD outputs
max. 14
Amount of semi-conductors auxilliary outputs
max. 14
Amount of semi-conductors clock outputs
max. 8
Input current
HIGH 2,4 mA ... 3,8 mA LOW -2,5 mA ... 2,1 mA
Output type
PNP- Semiconductor
Output voltage
Operating Voltage UB -0,5 V
Seperate output current
max. 600 mA (bei UB 24 V)
Total output current
max. 2 A (bei UB 24 V)
General data
Memory card
Installation of a memory card MEM SP-N-88-001-93 possible
Programming connection
Micro USB Wireless-Interface
- fine wired (wire sleeve with plastic collar)
0,08 … 0,5 mm²
Input voltage
HIGH 75% from UB (adjustable by software) LOW 25% from UB (adjustable by software)
Technical data inputs
Technical data safe OSSD outputs, auxilliary and test pulse outputs
Short-circuit proof
Yes
Mechanical data
Installation opening of buttons
22,5 mm
Type of housing
H06
Dimensions
Height
44 mm
Length
253 mm
Width
42 mm

Recommended