Recommended fuse
Fast Acting Fuse 2,5 A
90 mA
90 mA inactive mode, LED and relays not activated
110 mA
110 mA active mode with LED, relays not activated
210 mA
210 mA active mode, LED, I/O and 4 relays activated
Maximum output current transistor output
600 mA
Voltage drop when output 600 mA
0.5 V below supply voltage
Maximum total output current transistors
2000 mA
Operating temperature
-20 degrees Celsius to + 65 degrees Celsius
Operating altitude
Up to 2000 m
Storage temperature
-30 degrees Celsius to + 70 degrees Celsius
Relative operating humidity
10 -90 %
Terminals (spring)
32 (max 0,5 mm2 or 24 AWG)
Vibration in accordance with the standard
EN 60068-2-6
Shock stress in accordance with the standard
EN 60068-2-27
Relative operating humidity
10 -90 %
Mounting surface size
253 x 40 x 44 mm
Maximum size housing
253 x 42 x 44 mm
Weight S14RBLD/S16RBLD without holes/plugs
About 235/265 g
Enclosure material
PC + ABS, UL-certified material, ANSI/UL 94
Degree of protection, IEC 60529
IP 65
Ventilation enclosure
GORE-TEX membrane
Calculations for PFH-d61508
up to 10 years
Calculations for PFH-d13849-1
up to 20 years
Radio frequency channel number 1
2405 MHz
Radio frequency channel number 2
2410 MHz
Radio frequency channel number 3
2415 MHz
Radio frequency channel number 4
2420 MHz
Radio frequency channel number 5
2425 MHz
Radio frequency channel number 6
2430 MHz
Radio frequency channel number 7
2435 MHz
Radio frequency channel number 8
2440 MHz
Radio frequency channel number 9
2445 MHz
Radio frequency channel number 10
2460 MHz
Radio frequency channel number 11
2465 MHz
Radio frequency channel number 12
2470 MHz
Radio frequency channel number 13
2475 MHz
Radio frequency channel number 14
2480 MHz
Radio frequency channel number 15
2485 MHz
Radio frequency channel number 16
2490 MHz
Power supply
Internally supplied, no external supply to CAN-card
Current consumption
0,02 A at 24 VDC
Terminals (spring)
7 (max 0.5 mm2)
Selector for resistor
Position ON = 120 Ohm between H & LPosition 1 = no resistor